Bosch Solution 16 Plus System Trouble P001

Solution 16

User Guide

i

Syste m Tro u ble Eve nt Li st in g

When one or more trouble events are in effect, the keypad will display the SERVICE symbol indicating that something

requires attention. The table below lists all of the system troubles or system faults which can be present on the alarm panel.

Each trouble event that can be shown by the panel has been assigned a unique Trouble Event Number. This number is

used to identify the trouble event from the list shown in "Table 24: System Trouble / Fault Descriptions" on page 35.

To interpret the system trouble from the keypad do the following;

1) Enter program mode and then press [7] + [0] + [1] + [OK]. Alternatively you can press the [] at any time provide a

system trouble is present. The keypad will now show the first trouble event number in the display. Use the the [] and []

keys to scroll from one trouble event to the next.

2) To find out more detail on each specific trouble event you can either refer to the trouble event descriptions in the table

below or to view more specific information on the keypad press [OK] and the display will begin to scroll the trouble event

number, the device or module number, trouble text description 1 and then trouble text description 2. The display will

continure to scroll the description of the trouble event which is in focus.

3) To return to the trouble list, press the [MENU] key or the exit completely and return to normal state press and hold the

the [MENU] key down for 2 seconds.

How System Troubles Are Displayed

The following diagram shows the typical procedure and keypad displays for a panel with 3 system troubles. The trouble

shown are Panel Tamper, Panel AC Fail and Panel Date and Time Error.

Enter programming mode and then press MENU 7-0-1 + [OK]

F40-1

Press [] or []

F41-1

Press [] or []

F45-1

Press [] or []

End

Trouble Event Number

F00-Output #

F01-Output #

F02-Output #

F10-Zone #

F11-Zone #

F12-Zone #

F13-Zone #

F20-Zone Expander #

F21-Zone Expander #

F30-Keyfob #

F40-Panel #

F41-Panel #

F42-Panel #

F43-Panel #

F44-Panel #

F45-Panel #

F46-Panel #

F47-Panel #

34

Press [OK]

P001

Press [OK]

P001

Press [OK]

P001

Trouble Event

Description

Output Missing

Output Overload

Output Trouble

Zone Missing

Zone Tamper

Zone Sensor Watch

Zone Low Battery

Zone Module Expander Missing

Zone Module Expander Tamper

RF Keyfob User Low Battery

Panel Tamper

Panel AC Fail

Panel Low Battery

Panel Missing Battery

Panel Default PIN

Panel Date/Time

Panel Route 1

Panel Route 2

cASE

Scrolling

nO AC

Scrolling

cLOc

Scrolling

Device or

Module Number

OP00x

OP00x

OP00x

Zn0xx

Zn0xx

Zn0xx

Zn0xx

IE001

IE001

KF0xx

P001

P001

P001

P001

P001

P001

P001

P001

OPEn

ErrOr

Trouble Text

Trouble Text

Description #1

Description #2

LOst

LOAd

Short

NO

LOAd

LOst

cAse

Open

SEnSOr

ALErt

bAttry

LEvEl

LOSt

cASE

OPEn

LO

BAt

cASE

OPEn

NO AC

bAttry

LEvEl

NO

bAttry

dFAult

PIN

clOc

ErrOr

rEPOrt

rtE 1

rEPOrt

rtE 2

Bosch Security Systems 6/09 BLCC500U FTR1.03

Bosch Solution 16 Plus System Trouble P001

Source: https://www.manualslib.com/manual/907195/Bosch-Solution-16i.html?page=34